HayssenSandiacre Ultima SV 12-19HR Instruction Manual page 344

Table of Contents

Advertisement

Sercos Module Status LED
SERCOS LED
Steady Green
Flashing Green
Flashing Red
1 5 - 2 2 / R e v 1 5
SERCOS MODULE STATUS LED
Status
Communication ready
Establishing communica-
tion
No communication
SERCOS CARD LED INDICATORS
The module's three LED indicators show the state of the system. The
LEDs are located on the bezel of the 1756-M08SE and the
1756-M16SE modules. The LED on the right, marked by OK, indicates
the present health of the module and the communication status. To the
immediate left of the OK LED is the SERCOS Ring LED, which is
marked with a ring icon and displays the status of the SERCOS net-
work. The CP LED, on the left, displays the status of the SERCOS
Communication Phases and is for informational purposes only.
During power up, the module completes a self test that includes an
indicator test. All LEDs go red for one second, green for one second,
and off for one second.
H A Y S S E
Probable Cause
No faults or failures
System is still in the pro-
cess of establishing SER-
COS communication
Node address setting on
the drive module does not
match SERCOS controller
configuration
Loose fiber optic cable
Broken fiber optic cable
Receive fiber optic cable
connected to SERCOS
transmit connector & vice
versa
Figure 4: Positioning of LEDs
NSA N D I AC R E
®
Corrective Action
N/A
Wait for steady greed LED
status
Verify proper node switch
setting
Verify cable connections
Replace fiber optic cable
Check proper SERCOS
cable connections
U l t i m a S V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF