Knife Assembly
Linear Plunge
Knife (Optional)
1 = Knife Blade
1 1 - 3 8 / R e v 1 5
The linear plunge knife is housed in the front jaw assembly. Operating
in a forward and back motion, it plunges from the jaw area, cuts
through the film, and passes into a recess in the rear jaw. At the end of
the dwell time, the knife retracts back into the front jaw.
1
2
3
2 = Knife Adjusting Collars
Figure 18: Linear Plunge Knife
L
P
K
INEAR
LUNGE
NIFE
1 = Knife Adjusting Collar
Figure 19: Knife Blade Replacement
1.
Remove machine power and lockout the machine.
2.
Remove the left hand 10/24" screw.
H A Y S S E
2
3 = Air Cylinder
B
R
LADE
EPLACEMENT
1
2
2 = 10/24" screw