OK LED
Display
Off
The module is not operating
Flashing Green
The module has passed internal diagnos-
tics, but has not established active commu-
nications
Solid Green
Flashing Red
Solid Red
A potential nonrecoverable fault has
occurred
U l t i m a S V
SERCOS COMMUNICATION PHASE STATUS
CP LED Display
Solid Orange
OFF
Flashing Red
Alternating Red and Green
Flashing Green
Solid Green
MODULE STATUS
Module Status
• Data is being exchanged
• The module is in the normal operating state
• A major recoverable failure has occurred
• An NVS update is in progress
H A Y S S E
NSA N D I AC R E
Module Status
In Phase -1: Autobaud detection in progress.
In Phase 0: Looking for a closed ring
In Phase 1: Looking for active nodes
In Phase 2: Configuring nodes for communication
In Phase 3: Configuring device specific parameters
In Phase 4: Configured and active
Action
• Apply chassis power
• Verify the module is completely inserted
into the chassis and backplane
None, if you have not configured the mod-
ule
None. The module is ready for action.
If an NVS update is in progress, complete
the NVS update. If an NVS update is not in
progress: Reboot
• Reboot the module
• If the solid red persists, replace the module
®
15