Static Eliminator
Static Bar Connector
Cable
1 4 - 5 2 / R e v 1 5
C
S
ABLE
UPPORTS
Supports are used to guide the high voltage cables from the bars along
the frame of the machine to the power unit.
C
:
AUTION
Cables should always be kept at least ¼" away from the machine
frame, walls, and ceiling. If it must touch the machine, it should
be encased in plastic tubing.
To install the cable supports:
1.
Press the split bushing out of the eye.
2.
Apply bushing to the cable.
3.
Mount the eye.
4.
Press the bushing with the cable into the eye.
5.
Close the eye with pliers to clamp it to the cable.
The cable support should be mounted so it removes all strain and
motion from the cable where it enters the static bar and the power unit.
P
U
OWER
NIT
Mount the power unit to the machine frame (preferably on the side
away from the operator) or to a close wall or post.
Cable Connector for
2nd Static Bar
Figure 36: Power Supply Unit
Once the static bars have been mounted to the machine and the cable
supports have been installed, the power unit can be connected to the
static bars:
H A Y S S E
NSA N D I AC R E
®
Power Cable
U l t i m a S V