MANUAL FUNCTIONS
Use this screen to manually activate various machine functions and to access the Diagnostic
screen.
E
P
NGAGE
LATEN
C
T
ONTINUOUS
UBE
J
A
OG
UGER
J
A
OG
GITATOR
C
J
LOSE
AW
O
J
PEN
AW
K
NIFE
H
J
OME
AW
5 - 6 / R e v 1 5
Enables the platen. The function is ON until the pad is touched a sec-
ond time.
Advances the film manually without performing sealing operations.
Manually turns the auger screw while held ON. This function is used to
fill flights with product after a change over and before a trial run to
empty the filler hopper or to release a jammed auger.
Manually turns the agitator when held ON.
When touched, the jaws close. This function is useful when aligning
and testing the jaw close proximity switch.
Used to manually open the jaw. This function is useful when aligning
and testing the jaw close proximity switch
.
I
:
MPORTANT
If stagers are present, close the stager before closing the jaws to
prevent the stager from interfering with the jaws.
Fires the knife each time the pad is touched.
Returns the jaws to home position.