SERCOS Ring Status
SERCOS Ring LED
Solid Green
Flashing Red
Solid Red
OFF
Flashing Green
1 5 - 2 4 / R e v 1 5
SERCOS RING STATUS
Ring Status
The ring, drive, and axes are con-
figured and are actively communi-
cating through to the nodes on the
ring
The module has detected a setup
or configuration fault with the ring
The module has detected a hard-
ware or installation fault with the
ring
The module has detected no ring
data on its receiver or has not suc-
cessfuly completed phase 2
The ring, drive, or axes are not
configured but, at least one has
been identified
H A Y S S E
None
Check your system ssetup and configura-
tion as follows:
• Ensure drive and axes addresses are correct
• Remove excess axes from ring
• Verify application program has selected the
proper Ring Cycle Period and Baud Rate
Check your system hardware and installa-
tion as follows:
• Verify all cables are properly installed
• Verify the cable is of the correct type and
length
• Verify application program has configured
the module's ring transmit level to High
when using specified cables
• Verify the drive's transmit levels are set
appropriately
• Inspect cables for degradation
• Inspect drives for any faults and correct
them
Check your system and installation as fol-
lows:
• Verify all cables are properly installed
• Inspect cable for degradation and breakage
• Inspect drives for faults
Not a problem if the system has not been
configured. If you are having trouble config-
uring the ring, drive, and axes: Verify that
the application program is setup properly
for the equipment in use