Volumetric Feed System
1 4 - 6 2 / R e v 1 5
D
M
C
RIVE
OTOR
LUTCH
Collar
1.
Turn the Volumetric Off.
1.
Turn the collar until the 1/4-20 socket head bolt is easily
accessible.
2.
Loosen the 1/4-20 bolt so the collar can be turned.
Use a 3/16 Allen wrench or T-handle.
3.
Turn the collar clockwise or counterclockwise to adjust
slip:
Clockwise
Decreases Slip
4.
Test the slip:
a. Turn the Volumetric On.
b. Carefully grasp the feed plate.
c. If more or less slip is needed, continue adjusting the
collar until the desired slip is accomplished.
5.
Retighten the 1/4-20 socket head bolt.
H A Y S S E
S
A
LIP
DJUSTMENT
Counterclockwise
Increases Slip
NSA N D I AC R E
®
(6-C
9-C
)
UP AND
UP
U l t i m a S V