HayssenSandiacre Ultima SV 12-19HR Instruction Manual page 177

Table of Contents

Advertisement

Jaw Closed
Proximity Switch
Adjustment
U l t i m a S V
W
:
ARNING
Do not touch Start. Serious personal injury or damage to the
machine may occur.
I
:
MPORTANT
The proximity switch is set at the factory and does not
require adjustment unless the original setup is altered.
Machine power must be On for this procedure.
2
1=Proximity Switch
2=Red LED
Figure 5: Jaw Closed Proximity Switch
1.
Press the E-Stop push button.
2.
Push the jaws to the closed position.
3.
Lock the crank linkage parallel to the actuator shaft with
a clamp block.
4.
Loosen the two hex bolts that attach the bracket and move
the bracket away from the shaft end until the LED is
extinguished.
5.
Move the bracket toward the shaft end until the LED illu-
minates.
6.
Tighten the two hex bolts.
7.
Remove the clamp block.
J
C
P
AW
LOSED
ROXIMITY
J
AWS
1.
Clear all safety switches and Reset the machine.
2.
At the Main Run Screen, touch Manual Mode.
3.
Home the jaws.
4.
Touch Machine Setup.
The Machine Setup screen displays.
H A Y S S E
NSA N D I AC R E
3
4
1
3=Jam Nuts
4=Actuator Shaft
S
V
WITCH
ERIFICATION FOR
®