HayssenSandiacre Ultima SV 12-19HR Instruction Manual page 200

Table of Contents

Advertisement

How To Change End Seal Systems
Changing from
Resistance to
Quali-Seal
1 1 - 3 2 / R e v 1 5
1.
Turn all power to machine Off.
2.
Unplug the electrical disconnect for
the sealing jaw.
3.
Loosen guard mounting screws and remove guards.
4.
Remove cutoff knife.
5.
Loosen cap screws and remove the sealing jaws from the
carrier.
6.
If the machine is equipped with a hole punch, disconnect
the air lines at the stopcocks and turn stopcocks off.
7.
Mount the Quali-Seal jaws to the carrier.
I
:
MPORTANT
The pin must engage the slot and the groove in the mounting
block must engage the locating tongue in the carrier to ensure
proper alignment between front and rear jaw faces.
8.
If the machine is equipped with a hole punch, connect air
lines at the stopcocks and turn stopcocks on.
9.
Tighten cap screws.
10.
Carefully install the cutoff knife.
11.
Install the guards.
12.
Plug in the electrical disconnect for
the sealing jaw.
13.
Restore power.
H A Y S S E
Remove the wires from the
terminal strip in the jaw carrier
OR
terminator box.
Connect the wires to the
terminal strip in the jaw carrier
OR
terminator box
NSA N D I AC R E
®
U l t i m a S V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents