HayssenSandiacre Ultima SV 12-19HR Instruction Manual page 311

Table of Contents

Advertisement

Yamato
Dump Signal Delay
U l t i m a S V
SCALE DUMP-TIMING
The Yamato scale is usually interfaced in the master mode.
FB
WB
Dump signal
discharge
delay
Start
Delay
Default Setting - 500ms
Signal delay from the time the product leaves the weigh bucket. This
allows the product to fall to the discharge of the collating funnel before
the dump signal is sent to the bagger.
used for timing the product drop to the packaging
machine.
needs to expire as the product reaches the discharge of the
collating funnel on the scale.
delays the start of the bag cycle to get the product timed
for the jaw close or stager close.
H A Y S S E
NSA N D I AC R E
Collating Chute
Collating Funnel
Forming Tube
Stager
®
14
Feed Bucket
Weigh Bucket