HANGING
ETS OF
The volumetric feed may have several sets of cups for running various
packages and weights.
I
:
MPORTANT
Rubber retaining rings are provided on each half set of cups, top
and bottom to lock the cup into position. The same rings are
used for any size cups.
Retain and use these rings. Do not operate the volumetric feed
without O-rings in place on the feed cups.
1.
Turn all power to machine Off.
2.
Empty the cups.
3.
Spread the feed plate and trap door plate apart by turning
the volume adjustment switch on the volumetric operator
panel.
4.
Remove the cups to be replaced.
Remove upper cups first over the top of the upper plate.
5.
Put each new-sized cup back into position.
6.
Ensure each cup is seated firmly in its groove.
I
:
MPORTANT
The cup must seat firmly in its groove or the retaining ring does
not lock.
7.
Set the cup height to produce the correct volume of prod-
uct.
8.
Restore power.
D
P
H
UMP
LATE
EIGHT
To allow for clearance as the plate turns, adjust the dump plate up or
down according to cup size. Most volumetric feed systems allow man-
ual and electric adjustment. The plate is adjusted manually using the
hand crank or electronically using switches located in the operator con-
trols.