Integrated Auger Feed System Setup
1 4 - 6 8 / R e v 1 5
2.
Touch Auger Screen.
Auger Setup screen displays.
3.
Touch Auger Calibration.
Auger Calibration screen displays.
4.
Touch Checkweigh Feedback Rate O/I pad to enable the
option.
The pad illuminates when the option is active.
5.
Enter the trim value on the external checkweigher as the
feedback rate.
The default checkweigh feedback rate is
Values can range from 0.01 - 5.00 sec/unit.
M
S
ANUALLY
ETTING THE
If the actual package weight of the product is above or below the target
weight, the trim may be adjusted manually while continuing to run
product.
1.
From Filled Bags screen, touch Options.
Options screen displays.
2.
Touch Auger Screen.
Auger Setup screen displays.
3.
Compare the actual weight to the Target Weight display-
ing on the Auger Setup screen.
Actual weight is more than the
target weight
a. Select Trim (units)
Keypad displays
b. Key in an amount less than the
value displayed in Trimmed
Units
c. Touch Enter
The new Trimmed Units value dis-
plays.
I
:
MPORTANT
The Trimmed Units field displays the current trim value. This is
the value that will be increased or decreased when a value is
entered into the field labeled Trim (units).
H A Y S S E
0.20 sec/unit.
T
V
RIM
ALUE
Actual weight is less than
a. Select Trim (units)
Keypad displays
b. Key in an amount greater than
the value displayed in Trimmed
Units
c. Touch Enter
The new Trimmed Units value dis-
plays.
NSA N D I AC R E
®
target weight