Chapter 3 Wiring
Servo Drive Model
ASD-A2-0743-
ASD-A2-1043-
ASD-A2-1543-
ASD-A2-2043-
ASD-A2-3043-
ASD-A2-4543-
ASD-A2-5543-
ASD-A2-7543-
ASD-A2-1B43-
ASD-A2-1F43-
Note:
1. Box, () at the end of the servo drive model represents the model code of ASDA-A2.
Please refer to the model information of the product you purchased.
2. (△), in servo motor model represents encoder type. △= 1: incremental type, 20-bit;
△= 2: incremental type, 17-bit; △= 3: 2500 ppr; △= A: absolute type.
3. Box, () in servo motor model represents brake or keyway / oil seal.
4. Please use shielded twisted-pair cable for encoder wiring so as to reduce the interference of the noise.
5. The shield should connect to the
6. Please follow the Selection of Wire Rod when wiring in order to avoid the danger it may occur.
7. L = 3 - 20 m: 0.324 mm²-2C(AWG22-2C) – for connecting to +5V power and grounding
0.205 mm²-2P(AWG24-2P) – for signal cable
L = 21 - 50 m: 1.31 mm²-2C(AWG16-2C) – for connecting to +5V power and grounding
0.128 mm²-2P(AWG26-2P) – for signal cable
3-26
Encoder Wiring - Wire Diameter mm
Size
Number
Note*7
2C+2P
phase of SHIELD.
2
(AWG)
Specification
Standard Length
L = 3 to 20 m
L = 3 to 20 m
(UL2464)
(9.84 ft to 65.6 ft)
L = 21 to 50 m
L = 21 to 50 m
(UL20276)
(68.9 ft to 164 ft)
ASDA-A2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents