Chapter 8 Parameters
Default: 0x0
Control
Mode:
Range: -
Data Size: 32-bit
Format: Decimal
Settings:While the Bit 1 of P2-70 is set to 1 to read the pulse number, this
P0-53
ZDRT
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0x000F
Data Size: 16-bit
Format: Hexadecimal
Settings:
8-34
ALL
Unit: Pulse or PUU
parameter represents the pulse number of encoder absolute position.
While the Bit 1 of P2-70 is set to 0 to read the PUU number, this
parameter represents the PUU number of motor absolute position.
Display range for number of revolution:
0 ~1280000-1 (Pulse); -2147483648 to +2147483647 (PUU)
General Range Compare Digital Output –
Filtering Time
Panel / Software
ALL
Unit: ms
X: Filtering time for 1
UYZ: Reserved
While the value of the monitoring variable is changed within the range
between the setting values of P0-54 and P0-55, this parameter is used
to set the filter timing for the monitoring variable. The value of
monitoring variable will output after the filtering time determined by
parameter P0-53.
Communication
monitoring variable
st
ASDA-A2
Address: 006AH
006BH
Related Section: N/A