ASDA-A2
P1-46▲
GR3
Operational
Interface:
Default: 2500
Control
Mode:
Range: 20 ~ 320000
Data Size: 32-bit
Format: Decimal
Settings: The number of single-phase pulse output per revolution.
P1-47
SPOK Speed Reached (DO:SP_OK) Range
Operational
Interface:
Default: 10
Control
Mode:
Range: 0 ~ 300
Data Size: 16-bit
Format: Decimal
Settings: When the deviation between speed command and motor feedback
Pulse Number of Encoder Output
Panel / Software
ALL
Unit: Pulse
Setting range: 20 – 320000
The maximum output frequency of the hardware is 19.8 MHz.
Note: The following circumstances might exceed the max. allowable input
pulse frequency and occurs AL018:
1. Abnormal encoder
2. The motor speed is faster than the setting of P1-76.
Motor
Speed
3.
60
Panel / Software
S / Sz
Unit: rpm
speed is smaller than this parameter, then the digital output
DO.SP_OK (DO code is 0x19) is ON.
Communication
P
1
46
4
19.8
Communication
Chapter 8 Parameters
Address: 015CH
015DH
Related Section: -
10
6
Address: 015EH
015FH
Related Section: -
8-71