Chapter 8 Parameters
P3-02
PTL
Operational
Interface:
Default: 0x0006
Control
Mode:
Range: 0x0000 ~ 0x0008
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the followings:
P3-03
FLT
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the following:
8-138
Communication Protocol
Panel / Software
ALL
Unit: -
0: 7, N, 2 (MODBUS, ASCII)
1: 7, E, 1 (MODBUS, ASCII)
2: 7, O,1 (MODBUS, ASCII)
3: 8, N, 2 (MODBUS, ASCII)
4: 8, E, 1 (MODBUS, ASCII)
5: 8, O, 1 (MODBUS, ASCII)
6: 8, N, 2 (MODBUS, RTU)
7: 8, E, 1 (MODBUS, RTU)
8: 8, O, 1 (MODBUS, RTU)
MODBUS Communication Error Disposal
Panel / Software
ALL
Unit: -
0: Show warning and the motor keeps running
1: Show warning and the motor decelerates to stop (The deceleration
time is set to parameter P5-03.B)
Communication
Communication
ASDA-A2
Address: 0304H
0305H
Related Section:
9.2
Address: 0306H
0307H
Related Section:
9.2