Delta ASD-A2-0121 Series User Manual page 477

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

Chapter 8 Parameters
P5-38■
CANO CAPTURE-The Number of Capturing Times
Operational
Interface:
Default: 1
Control
Mode:
Range: 1 ~ (the value set by P5-10 minus the value
Data Size: 16-bit
Format: Decimal
Settings: When CAPTURE stops, it means the number of data that expect to
P5-39■
CACT CAPTURE-Activate CAP Control
Operational
Interface:
Default: 0x2010
Control
Mode:
Range: 0x0000 ~ 0xF13F
Data Size: 16-bit
Format: Hexadecimal
8-178
Panel / Software
ALL
Unit: -
set by P5-36)
capture (readable and writable).
When CAPTURE activates, it means the number of data that has not
been captured (read-only); every time, when it captures one data, the
value of P5-38 will subtract one. When the value is 0, it means the
capturing is completed.
Note: 1. The number of data which is used by COMPARE, CAPTURE, and
E-Cam cannot exceed 800.
2. A2-L does not support E-Cam function.
Panel / Software
ALL
Unit: -
Communication
Communication
ASDA-A2
Address: 054CH
054DH
Related Section:
7.11.1
Address: 054EH
054FH
Related Section:
7.11.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents