Delta ASD-A2-0121 Series User Manual page 208

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2
P1-35
TDEC Deceleration Constant of S-Curve
Operational
Interface:
Default: 200
Control
Mode:
Range: 1 ~ 65500
Data Size: 16-bit
Format: Decimal
Settings: Deceleration Constant of Speed:
P1-36
TSL
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 65500 (0: disable this function)
Data Size: 16-bit
Format: Decimal
Panel / Software
S
Unit: ms
P1-34, P1-35, P1-36, and the deceleration time of speed command
from the rated speed to zero all can be set individually. Even when
P1-36 is set to 0, it still has acceleration / deceleration of trapezoid-
curve.
Note: 1)When the source of speed command is analog, and P1-36 is set to
0, it will disable S-curve function.
2)When the source of speed command is analog, the max. range of
P1-35 will be set within 20000 automatically.
Acceleration / Deceleration Constant of S-
Curve
Panel / Software
S / PR
Unit: ms
Chapter 6 Control Mode of Operation
Communication
Communication
Address: 0146H
0147H
Related Section:
6.3.3
Address: 0148H
0149H
Related Section:
6.3.3
6-11

Hide quick links: