Chapter 8 Parameters
P1-03
AOUT Polarity Setting of Encoder Pulse Output
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0x0013
Data Size: 16-bit
Format: Hexadecimal
Settings:
P1-04
MON1 MON1 Analog Monitor Output Proportion
Operational
Interface:
Default: 100
Control
Mode:
8-44
When desiring to use the torque limit function, users could use
parameter to set this value to 1 and limit the torque for good.
Thus, the user can save one DI setting. Also, users could enable
or disable the limit function via DI.TRQLM, which is a more
flexible way but would need to take one DI setting. Torque limit
can be enabled by P1-02 or DI.
DI.TCM0 and DI.TCM1 are for selecting the limiting source.
Panel / Software
ALL
Unit: -
Polarity of monitor analog output
0: MON1(+), MON2(+)
1: MON1(+), MON2(-)
Polarity of encoder pulse output
0: Forward output
Panel / Software
ALL
Communication
Polarity of monitor analog output
Polarity of encoder pulse output
Not in use
2: MON1(-), MON2(+)
3: MON1(-), MON2(-)
1: Reverse output
Communication
ASDA-A2
Address: 0106H
0107H
Related Section:
3.3.3
Address: 0108H
0109H
Related Section:
6.4.4