(kW)
Medium-
11.0 ECMA- F△221B
High
Inertia
15.0 ECMA- F△221F
0.4
ECMA-G△1303
0.75 ECMA-F△1305
High
Inertia
0.75 ECMA-G△1306
1.0
ECMA-G△1309
Eo= J * wr
2
/182 (joule), Wr: r/min
400V
Servo Drive
(kW)
0.75 ECMA-J△0604
0.75 ECMA-J△0807
0.75 ECMA-J△0907
Low
Inertia
1.0
ECMA-J△0910
1.5
ECMA-J△1010
2.0
ECMA-J
0.75 ECMA-K△1305
1.0
ECMA-K△1310
Medium
1.5
ECMA-K△1315
Inertia
2.0
ECMA-K△1320
2.0
ECMA-K△1820
2-14
Rotor Inertia
Motor
J (× 10
329.0
553.0
8.17
10.3
8.41
11.18
Rotor Inertia
Motor
J (× 10
1020
Regenerative power
from empty load
3000 r/min to stop
kg.m2)
-4
Eo (joule)
723.08
1215.38
17.96
22.64
18.48
24.57
Regenerative
power from empty
load 3000 r/min to
-4
kg.m2)
stop Eo (joule)
0.277
1.37
1.13
5.59
1.93
9.54
2.62
12.96
2.65
13.10
4.45
22.01
8.17
40.40
8.41
41.59
11.18
55.29
14.59
72.15
34.68
171.49
Chapter 2 Installation
The maximum
regenerative power of
capacitance
Ec (joule)
117
156
8.42
17.47
17.47
21.22
The maximum
regenerative power
of capacitance
Ec (joule)
42.43
42.43
42.46
42.43
42.43
42.43
51.17
51.17
57.41
34.94
34.94

Hide quick links: