Chapter 8 Parameters
P1-56
OVW
Operational
Interface:
Default: 120
Control
Mode:
Range: 0 ~ 120
Data Size: 16-bit
Format: Decimal
Settings: The setting value is 0 ~ 100, if the servo motor continuously outputs
P1-57
CRSHA Motor Crash Protection (torque percentage)
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 300
Data Size: 16-bit
Format: Decimal
Settings: Setup protection level (for the percentage of rated torque, set the value
8-78
Output Overload Warning Level
Panel / Software
ALL
Unit: %
the load and is higher than the setting proportion (P1-56), the early
warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.
Panel / Software
ALL
Unit: %
to 0 means to disable the function; set the value to 1 or number above
means to enable the function)
Communication
Communication
ASDA-A2
Address: 0170H
0171H
Related Section: -
Address: 0172H
0173H
Related Section: -