Delta ASD-A2-0121 Series User Manual page 348

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2
P1-12
TQ1
Operational
Interface:
Default: 100
Control
Mode:
Range: -380 ~ +380 *
Data Size: 16-bit
Format: Decimal
Example: Internal Torque Command: 30 = 30%
Settings:
P1-13
TQ2
Operational
Interface:
Default: 100
Control
Mode:
Range: -380 ~ +380 *
Data Size: 16-bit
Internal Torque Command 1/Internal Torque
Limit 1
Panel / Software
T / P, S
Unit: %
Internal Torque Limit: Positive value and
negative value is the same. Please refer to
the following description.
Internal Torque Command 1: The setting of the first internal torque
command
Internal Torque Limit 1: The setting of the first internal torque limit
Example of inputting internal torque limit:
Torque limit
setting value
of P1-12
30
-30
Note: please refer to the motor specification for the actual motor torque. If the
actual maximum motor torque is 300%, the actual torque output will be
300% even when this parameter is set to 380%.
Internal Torque Command 2/Internal Torque
Limit 2
Panel / Software
T / P, S
Unit: %
Communication
1
Allowable
Torque Range
-30 ~ 30%
Communication
1
Chapter 8 Parameters
Address: 0118H
Related Section:
6.4.1
Forward Torque
Reverse Torque
Limit
30%
Address: 011AH
Related Section:
6.4.1
0119H
Limit
-30%
011BH
8-49

Hide quick links:

Advertisement

Table of Contents
loading