Delta ASD-A2-0121 Series User Manual page 180

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2
please set this DI as normally open (function code: 0x0123).
6) When the screen displays:
Warning of overcurrent:
Corrective Action:
Check the connection between the motor and servo drive.
Check if the conducting wire is short-circuited. Exclude short circuit and avoid metal
conductors being exposed.
7) When the screen displays:
Warning of undervoltage:
Corrective action:
Check if the wiring of main circuit input voltage is correct.
Use the voltmeter to measure if the main circuit voltage is normal.
Use the voltmeter to measure if the power system complies with the specification.
Note: During the process of power on or servo on, if an alarm occurs or shows any abnormal
display, please contact the distributors.
Chapter 5 Trial operation and Tuning
5-5

Hide quick links: