ASDA-A2
Range: 10 ~ 1073741823,
Data Size: 32-bit
Format: Decimal
Settings: When receiving pulse number P of the Master, E-Cam will rotate M
P5-85
ECME E-CAM: Number of Area
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ (P5-82-1)
Data Size: 16-bit
Format: Decimal
Settings: The area number of E-cam when E-cam engaged.
P5-86■
ECAX E-CAM: Master Axis Position
Operational
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
and P5-82 x P5-83 <= P5-84
and P5-82 x P5-84 <= 2147483647
circle, which means the M cycle of the E-Cam table.
Note: 1. This parameter can be written when E-Cam stops (Please refer
toP5-88, X=0).
2. Version V1.018 (included or after): This parameter can be modified
anytime, and has no limit that mentioned above.
3. A2-L does not support E-Cam function.
Panel / Software
PR
Unit: -
Note: A2-L does not support E-Cam function.
Panel / Software
PR
Unit: -
Communication
Communication
Chapter 8 Parameters
Address: 05AAH
05ABH
Related Section:
7.11
Address: 05ACH
05ADH
Related Section:
7.11
8-203