Chapter 8 Parameters
Settings: When increasing integral compensation to synchronous position, two
SBW
P2-57
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1023
Data Size: 16-bit
Format: Decimal
Settings: If users do not know how to set P2-54 ~ P2-56, setting the bandwidth
P2-58
SVL
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1000
Data Size: 16-bit
Format: Decimal
Example: 15 = 1.5 ms
Settings: If the synchronous control is influenced by low resolution and causes
8-120
motors speed following can be enhanced and the speed error between
two motors can be reduced. However, if the value is set too big, it may
easily cause vibration and noise It is suggested to set the value the
same as P2-06.
The Bandwidth of Synchronous Control
Panel / Software
ALL
Unit: Hz
of synchronous control value will do since the value will correspond to
P2-54 ~ P2-56. The bigger the bandwidth of synchronous control value
is, the better the synchronous effect will be. When the bandwidth of
speed loop plus the bandwidth of synchronous control is greater than
the system's allowable bandwidth, it causes system resonance. When
increasing the bandwidth of speed loop and synchronous control, pay
special attention to the response of P2-25 which should be faster than
the setting of the both bandwidth.
Low-pass Filter of Synchronous Speed Error
Panel / Software
ALL
Unit: 0.1 ms
noise (not a high-pitched but rough sound), low-pass filter can be used
to solve this problem. Please note that bandwidth of the synchronous
control should be set as large as possible and should larger than the
bandwidth of speed-loop.
Communication
Communication
ASDA-A2
Address: 0272H
0273H
Related Section: -
Address: 0274H
0275H
Related Section: -