Delta ASD-A2-0121 Series User Manual page 487

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

Chapter 8 Parameters
Settings: When COMPARE stops, it means the number of data that expect to
P5-59
CMCT COMPARE-Activate CMP Control
Operational
Interface:
Default: 0x00640010
Control
Mode:
Range: 0x00010000 ~ 0x0FFF313F
Data Size: 32-bit
Format: Hexadecimal
8-188
compare (readable and writable).
When COMPARE activates, it means the number of data that has not
been compared (read-only); every time, when it compares one data,
the value of P5-38 will subtract one. When the value is 0, it means the
comparing is completed.
Panel / Software
ALL
Unit: -
Communication
ASDA-A2
Address: 0576H
0577H
Related Section:
7.11.2