Chapter 8 Parameters
P1-48
MCOK
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0x0011
Data Size: 16-bit
Format: Hexadecimal
Settings: Control selection of digital output DO.MC_OK (DO code is 0x17).
8-72
Block diagram:
1. Speed command: It is the command issued by the user (without
acceleration / deceleration), not the one of front end speed circuit.
Source: Analog voltage and register
2. Feedback speed: The actual speed of the motor and have gone
through the filter.
3. Obtain the absolute value.
4. DO.SP_OK will be ON when the absolute value of speed error is
smaller than P1-47, or it will be OFF. If P1-47 is 0, DO.SP_OK is
always OFF.
Operation Selection of Motion Reached
(DO.MC_OK)
Panel / Software
PR
Unit: -
(It will be available after firmware version V1.003 sub08)
The format of this parameter: 00YX
X=0: It will not remain the digital output status
1: It will remain the digital output status
Y=0: AL380 (position deviation) is not working
1: AL380 (position deviation) is working
Communication
ASDA-A2
Address: 0160H
0161H
Related Section: -