Chapter 8 Parameters
Settings: Special-bit Register 2:
P2-67
JSL
Operational
Interface:
Default: 1.5
Control
Mode:
Range: 0 ~ 200.0
Data Size: 16-bit
Format: One decimal
Example: 1.5 = 1.5 times
8-126
Bit7
Bit6
Bit15
Bit14
Bit0 ~ Bit1: Reserved
Bit2: Cancel latch function of low-voltage error
0: Latch function of low-voltage error: the error will not be cleared
automatically.
1: Cancel latch function of low-voltage error: the error will be cleared
automatically.
Bit3: Reserved
Bit4: Cancel the detection of AL044
0: AL044 will occur
1: AL044 will be ignored
Bit5: Enable disconnection detection of linear scale (only when the full-
closed loop control function is enabled)
0: AL041 will be ignored
1: AL041 will occur
Bit6 ~ Bit8: Reserved
Bit9: Set AL003 as ALM or WARN
0: Set AL003 as WARN
1: Set AL003 as ALM
Bit10 ~ Bit11: Reserved
Bit12: Set AL022 as ALM or WARN
0: Set AL022 as WARN
1: Set AL022 as ALM
Bit13 ~ Bit15: Reserved
The Stable Level of Inertia Estimation
Panel / Software
ALL
Unit: 1 times
Bit5
Bit4
Bit3
Bit13
Bit12
Bit11
Communication
15
0.1 times
0 ~ 2000
Decimal
15 = 1.5 times
ASDA-A2
Bit2
Bit1
Bit0
Bit10
Bit9
Bit8
Address: 0286H
0287H
Related Section: -