ASDA-A2
AL074:Absolute encoder single turn position error
Causes
Absolute encoder single
turn position error
AL075:Absolute encoder position error
Causes
Absolute encoder position
error
AL077:Encoder computing error
Causes
Encoder internal error
(internal computing error)
10-24
Checking Method
1. Check if the motor is well
grounded.
2. Check if the encoder cable is
separated from the power
supply or any high-current cable
to avoid interference.
3. Check if the encoder uses
shielded cable.
4. Check the motor speed.
Checking Method
1. Check if the motor is well
grounded.
2. Check if the encoder cable is
separated from the power
supply or any high-current cable
to avoid interference.
3. Check if the encoder uses
shielded cable.
4. Check the motor speed.
Checking Method
1. Check if the motor is well
grounded.
2. Check if the encoder cable is
separated from the power
supply or any high-current cable
to avoid interference.
3. Check if the encoder uses
shielded cable.
4. Check the motor speed.
Chapter 10 Troubleshooting
Corrective Actions
1. Make sure the UVW connector
is grounded to the heat sink of
the servo drive.
2. Make sure the encoder signal
cable is separated from the
power supply or any high-
current cable.
3. Use shielded cable for the
encoder.
4. Make sure the motor speed is
within the rated range.
5. If the issue persists, please
send your servo drive back to
the distributor or contact Delta.
Corrective Actions
1. Make sure the UVW connector
is grounded to the heat sink of
the servo drive.
2. Make sure the encoder signal
cable is separated from the
power supply or any high-
current cable.
3. Use shielded cable for the
encoder.
4. Make sure the motor speed is
within the rated range.
5. If the issue persists, please
send your servo drive back to
the distributor or contact Delta.
Corrective Actions
1. Make sure the UVW connector
is grounded to the heat sink of
the servo drive.
2. Make sure the encoder signal
cable is separated from the
power supply or any high-
current cable.
3. Use shielded cable for the
encoder.
4. Make sure the motor speed is
within the rated range.
5. If the issue persists, please
send your servo drive back to
the distributor or contact Delta.

Hide quick links: