Chapter 8 Parameters
Format: Hexadecimal
Settings: Format: U Z Y X
Note: This parameter is effective only after you cycle power to the servo drive. You
P2-70
MRS
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0x0007
Data Size: 16-bit
Format: Hexadecimal
Settings:
8-128
X: Setup the operation mode
0: Incremental mode. Servo motor with absolute encoder can be
operated as incremental motor.
1: Absolute mode. (This setting is only available for the servo motor
with absolute encoder. When an incremental servo motor is
connected, AL069 will occur.)
Y: Setup the pulse command when absolute position is lost
0: When AL060 or AL06A occurs, it cannot accept pulse command
1: When AL060 or AL06A occurs, it can accept pulse command
Z: Function setting when index coordinates overflow
0: Index coordinates is lost when overflows
1: Index coordinates will not overflow, but absolute coordinates
(Fb_PUU)will not remain
U: Reserved
can establish the absolute origin coordinates after completing setting this
parameter.
Read Data Format Selection
Panel / Software
ALL
Unit: -
Bit7
Bit6
Bit15
Bit14
Bit 0: Data unit setting of digital input/output (DI/DO); 1: Pulse, 0: PUU
Bit 1: Communication data unit setting; 1: Pulse, 0: PUU
Bit 2: Overflow warning; 1: No overflow warning,
Communication
Bit5
Bit4
Bit3
Bit13
Bit12
Bit11
0: Overflow warning, AL289 (PUU),
ASDA-A2
Address: 028CH
028DH
Related Section: N/A
Bit2
Bit1
Bit0
Bit10
Bit9
Bit8
AL062 (number of turns).