Chapter 8 Parameters
Settings: Four items: UZYX
P5-99
EVOF PR# Triggered by Event Falling-Edge
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0xDDDD
Data Size: 16-bit
Format: Hexadecimal
Settings: Four items: UZYX
8-224
When EVx is set to ON, the PR# will be executed.
X=0: When EV1 is ON, PR will not be triggered.
X=1 ~ D: When EV1 is ON, execute PR # 51 ~ 63.
Y=0: When EV2 is ON, PR will not be triggered.
Y=1 ~ D: When EV2 is ON, execute PR # 51 ~ 63.
Note: EV3 and EV4 are supported after firmware V1.009.
Z=0: When EV3 is ON, PR will not be triggered.
Z=1 ~ D: When EV3 is ON, execute PR # 51 ~ 63.
U=0: When EV3 is ON, PR will not be triggered.
U=1 ~ D: When EV4 is ON, execute PR # 51 ~ 63.
Panel / Software
PR
Unit: -
When EVx is set to OFF, the PR# will be executed.
X=0: When EV1 is OFF, PR will not be triggered.
X=1 ~ D: When EV1 is OFF, execute PR # 51 ~ 63.
Y=0: When EV2 is OFF, PR will not be triggered.
Y=1 ~ D: When EV2 is OFF, execute PR # 51 ~ 63.
Note: EV3 and EV4 are supported after firmware V1.009.
Z=0: When EV3 is OFF, PR will not be triggered.
Z=1 ~ D: When EV3 is OFF, execute PR # 51 ~ 63.
U=0: When EV4 is OFF, PR will not be triggered.
U=1 ~ D: When EV4 is OFF, execute PR # 51 ~ 63.
Communication
ASDA-A2
Address: 05C6H
05C7H
Related Section: -