Chapter 8 Parameters
Range: 0 ~ 6
Data Size: 16-bit
Format: Decimal
Settings: 0: reserved
P4-11
SOF1
Operational
Interface:
Default: Factory default
Control
Mode:
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually calibrate the hardware offset. The calibration function needs
8-152
1: Execute the calibration of analog speed input offset
2: Execute the calibration of analog torque input offset
3: Execute the calibration of current detector (V phase) hardware offset
4: Execute the calibration of current detector (W phase) hardware
offset
5: Execute the calibration of 1 ~ 4 hardware offset
6: Execute the calibration of IGBT ADC
Note: The calibration function needs to be enabled by P2-08. When
calibration, the external wiring which connects to analog speed or
torque needs to be removed completely and must be in Servo Off
status.
Analog Speed Input Offset Adjustment 1
Panel / Software
ALL
Unit: -
to be enabled by P2-08. It is not suggested to adjust the auxiliary
calibration function. This parameter cannot be reset.
Communication
ASDA-A2
Address: 0416H
0417H
Related Section: -