ASDA-A2
Range: 0 ~ 1000
Data Size: 16-bit
Format: Decimal
Settings: The smooth constant of analog position command is only effective to
Note: This function is available for firmware version v1.031 sub8 and above.
P1-66
PCM
Operational
Interface:
Control Mode: PT
Data Size: 16-bit
Example: 1.5 = 1.5 cycles
Settings: It is the rotation number setting when analog speed command
Note: This function is available for firmware version v1.031 sub8 and above.
P1-67
Reserved
P1-68
PFLT2 Position Command Moving Filter
Operational
Interface:
Default: 4
Control
Mode:
analog position command.
Max. Rotation Number of Analog Position
Command
Panel / Software
Default: 0.0
Unit: 1 cycle
Range: 0.0 ~ 200.0
Format: One decimal
inputs the max. voltage (10V). If it is set to 3.0 and the external
voltage inputs 10V, it means the position command is +3 cycles.
5V means the speed control command is 1.5 cycles.
-10V means the position command is -3 cycles.
Position control command = Input voltage value x Setting value/10
Panel / Software
PT / PR
Unit: ms
Communication
0
0.1 cycle
0 ~ 2000
DEC
15 = 1.5 cycles
Communication
Chapter 8 Parameters
Address: 0184H
0185H
Related Section: -
Address: 0188H
0189H
Related Section: -
8-83