ASDA-A2
Motor Cable Selection and Installation Precautions
The selection of motor cables and installation affects the performance of EMI Filter. Please follow
the precautions below.
1. Use the cable that has braid shielding. (The effect of double shielding is better.)
2. The shield on both sides of the motor cable should be grounded in the shortest distance and
the largest contact area.
3. The protective paint of the U-shape saddle and metal plate should be removed in order to
ensure good contact. Please see the figure below.
4. It should have a correct connection between the braid shielding of the motor cable and the
metal plate. The braid shielding on both sides of the motor cable should be fixed by the U-
shape saddle and metal plate. Please see the figure below for the correct connection.
(1) The protective paint of the U-shape saddle and metal plate should be removed in
order to ensure good contact.
(2) U-shape saddle
(3) Well-grounded metal plate