ASDA-A2
Control
Mode:
Range: 0 ~ 2
Data Size: 16-bit
Format: Decimal
Settings: 0: The value of P2-43, P2-44 and P2-45, P2-46 will retain.
P2-48
ANCL Resonance Suppression Detection Level
Operational
Interface:
Default: 100
Control
Mode:
Range: 1 ~ 300
Data Size: 16-bit
Format: Decimal
Settings: (The smaller the setting value is, the more sensitive the resonance will
ALL
Unit: -
1: The value of P2-43, P2-44 and P2-45, P2-46 will retain after
resonance suppression.
2: Continuous resonance suppression
Description of Auto Mode Setting:
When it is set to 1: Auto resonance, the value returns to 0
When it is set to 2: Continuous suppression automatically. When it is
When switching to mode 0 from mode 2 or 1, the setting of P2-43,
P2-44, P2-45 and P2-46 will be saved automatically.
Panel / Software
ALL
Unit: -
be.)
P2-48↑, resonance sensitiveness↓
P2-48↓, resonance sensitiveness↑
automatically and saves the point of resonance
suppression when it is stable. If it is unstable,
re-power on or set back to 1 for re-estimation again.
stable, the point of resonance suppression will be
saved. If it is unstable, re-power on for re-
estimation.
Communication