Delta ASD-A2-0121 Series User Manual page 492

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2
P5-65
POV5
Operational
Interface:
Default: 500.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Format: Decimal
Example: 1= 1 r/min
Settings: The 6
P5-66
POV6
Operational
Interface:
Default: 600.0
Control
Mode:
Range: 0.1 ~ 6000.0
Data Size: 16-bit
Format: Decimal
Example: 1= 1 r/min
Settings: The 7
Target Speed Setting #5
Panel / Software
PR
Unit: 1 r/min
target speed of PR mode
th
Target Speed Setting #6
Panel / Software
PR
Unit: 1 r/min
th
target speed of PR mode
Communication
5000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Communication
6000
0.1 r/min
1 ~ 60000
10 = 1 r/min
Chapter 8 Parameters
Address: 0582H
0583H
Related Section:
7.10
Address: 0584H
0585H
Related Section:
7.10
8-193