Delta ASD-A2-0121 Series User Manual page 384

Ac servo drive for network communication applications
Hide thumbs Also See for ASD-A2-0121 Series:
Table of Contents

Advertisement

ASDA-A2
P1-73
FERR
Operational
Interface:
Default: 30000
Control
Mode:
Range: 1 ~ (2
Data Size: 32-bit
Format: Decimal
Settings: The protection is for excessive deviation between feedback position of
P1-74▲
FCON
Operational
Interface:
Default: 0x0000
Control
Mode:
Unit: -
Range: 0x0000 ~ 0x4122
Data Size: 16-bit
Format: Hexadecimal
Settings:
Error Protection Range for Full-closed Loop
Control
Panel / Software
PT
Unit: Pulse (based on the feedback of full-closed
loop)
31
-1)
linear scale A/B Counter and the encoder. When the deviation is
excessive, it might result from the loose of connector or other
mechanism problems.
Full-closed Loop Control of Linear Scale
Panel / Software
PT
Communication
Communication
Switch of full-closed loop
Selection of OA/OB/OZ output source
Positive/negative direction selection of linear
scale feedback
Filter setting of linear scale
Not in use
Chapter 8 Parameters
Address: 0192H
0193H
Related Section:
P2-34
Address: 0194H
0195H
Related Section:
P1-46
8-85