The most important parameters
Table 6-57
Parameter
p0342
p1496
p1452
p1470
p1472
Table 6-58
Parameter
p0342
p1496
p1441
p1442
p1460
p1462
6.21.3.5

Advanced settings

K
- and T
adaptation
P
I
K
and T
p
measurement" of the motor data identification optimizes the speed controller. If you have
performed the rotating measurement, then the K
You can find additional information in the List Manual:
● Vector control with speed controller: Function diagram 6050
● Vector control after presetting the application class Dynamic Drive Control Function
diagram 6824
Droop
For mechanically coupled drives, there is the risk that the drives oppose one another: Small
deviations in the speed setpoint or actual value of the coupled drives can mean that the drives
are operated with significantly different torques.
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Encoderless speed control
Description
Moment of inertia ratio, total to motor (factory setting: 1.0)
Acceleration precontrol scaling (factory setting: 0 %)
For the rotating measurement of the motor data identification the inverter sets the pa‐
rameters to 100 %.
Speed controller speed actual value smoothing time (without encoder) (factory setting:
10 ms)
Speed controller operation without encoder P gain (factory setting: 0.3)
Speed controller operation without encoder integral action time (factory setting: 20 ms)
Speed control with encoder
Description
Moment of inertia ratio, total to motor (factory setting: 1.0)
Acceleration precontrol scaling (factory setting: 0 %)
For the rotating measurement of the motor data identification the inverter sets the pa‐
rameters to 100 %.
Speed controller smoothing time (factory setting: 0 ms)
Speed controller speed actual value smoothing time (factory setting: 4 ms)
Speed controller operation without encoder P gain (factory setting: 0.3)
Speed controller operation without encoder integral action time (factory setting: 20 ms)
adaptation suppress speed control oscillations that may occur. The "rotating
I
Advanced commissioning
- and T
adaptation has been set.
p
n
6.21 Motor control
303