03/2006
3.8

PCU 20/50/50.3/70

3.8.1
Settings with HMI Embedded/HMI Advanced for
SINUMERIK 840D
BTSS (standard)
The operating panel interface (BTSS) is the default setting (1.5 MBaud).
S
S
Setting the display
The display machine data (BTSS settings) are set via the user interface of the
machine data
HMI in the Start-up area "Start-up" –> "Machine data".
Language
S
S
Screen saver mode
MD 9006 (for HMI Embedded):
This MD is used to enter the time after which the screen saver mode is activa-
ted if no key is pressed on the operating panel within the specified time.
A detailed description of the functions and parameter settings can be found in
the following documentation:
Reference material: /IAM/ Start-up Guide, IM2, HMI Embedded
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
PCU 20 with HMI Embedded
HMI Embedded automatically adjusts to the baud rate.
PCU 50/50.3/70 with HMI Advanced
The HMI Advanced must be set to a baud rate of 1.5 MBaud in the "Start-up/
HMI/Operating panel" menu.
PCU 20 with HMI Embedded
The HMI Embedded software is available in six languages by default
(English, German, French, Italian, Spanish and simplified Chinese).
PCU 50/50.3/70 with HMI Advanced
HMI Advanced is always supplied as a multilingual version. The default
setting is English.
3 Settings, MPI/BTSS
3.8
PCU 20/50/50.3/70
IM4, HMI Advanced
3
3-33