Register Description - NXP Semiconductors PN7462 series User Manual

Table of Contents

Advertisement

NXP Semiconductors
Name
INTERNAL_USE
CLIF_ANA_TX_SHAPE_CONTROL
_REG
INTERNAL_USE
CLIF_ANA_TEST_REG
INTERNAL_USE
INTERNAL_USE
CLIF_DPLL_INIT_REG
INTERNAL_USE
INTERNAL_USE
INTERNAL_USE
INTERNAL_USE
CLIF_INT_CLR_ENABLE_REG
CLIF_INT_SET_ENABLE_REG
CLIF_INT_STATUS_REG
CLIF_INT_ENABLE_REG
CLIF_INT_CLR_STATUS_REG
CLIF_INT_SET_STATUS_REG

12.6 Register description

Table 186. CLIF_CONTROL_REG register (address 0000h)
* = reset value
Bit
Symbol
31:4
RESERVED
3
START_SEND
2:0
COMMAND
UM10858
User manual
COMPANY PUBLIC
Address
Width
offset
(bits)
0124h
32
0128h
32
012Ch
32
01FCh
32
0200h
32
0204h
32
0208h
32
020Ch
32
0210h
32
0214h
32
0218h
32
3FD8h
32
3FDCh
32
3FE0h
32
3FE4h
32
3FE8h
32
3FECh
32
Access
Value
Description
R
0
Reserved
D
0*, 1
Set to logic 1, the data transmission is started.
Note: This bit is only valid in combination with the transceive command
Note: If TXWait is set to a value other than zero the TXWait period
configured must be expired as well that the transmission starts
As soon as the transmission started this bit is cleared by hardware.
D
0 - 5
These registers hold the command bits
0*
IDLE/StopCom Command; stops all ongoing communication and set
the CLIF to IDLE mode; reset value
1
Transmit command; starts a transmission immediately
2
Receive command; enables the receiver. After end of reception the bits
are clear and IDLE
3
Transceive command; initiates a transceive cycle.
Note: Depending on the value of the Initiator bit a transmission is
started or the receiver is enabled
All information provided in this document is subject to legal disclaimers.
Rev. 1.4 — 14 May 2018
Access
Reset value Description
R/W
00000000h
R/W
00000000h
R/W
00000000h
R/W
0050004Ah
R/W
FF000000h
R/W
00000000h
R/W
00000000h
R/W
00000000h
R/W
00000000h
R/W
00000000h
R/W
00000000h
W
00000000h
W
00000000h
R
00000000h
R
00000000h
W
00000000h
W
00000000h
314514
UM10858
PN7462 family HW user manual
For internal use
Analog TX shaping control register
For internal use
Analog test control register
For internal use
For internal use
DPLL Configuration Register
For internal use
For internal use
For internal use
For internal use
Interrupt register
Interrupt register
Interrupt register
Interrupt register
Interrupt register
Interrupt register
© NXP B.V. 2018. All rights reserved.
155 of 345

Advertisement

Table of Contents
loading

Table of Contents