NXP Semiconductors PN7462 series User Manual page 117

Table of Contents

Advertisement

NXP Semiconductors
Bit
Symbol
23
GPIO8_PAD_HIGH_INT_S
ET_STATUS
22
GPIO7_PAD_HIGH_INT_S
ET_STATUS
21
GPIO6_PAD_HIGH_INT_S
ET_STATUS
20
GPIO5_PAD_HIGH_INT_S
ET_STATUS
19
GPIO4_PAD_HIGH_INT_S
ET_STATUS
18
GPIO3_PAD_HIGH_INT_S
ET_STATUS
17
GPIO2_PAD_HIGH_INT_S
ET_STATUS
16
GPIO1_PAD_HIGH_INT_S
ET_STATUS
15:11
RESERVED
10
VBUSP_MON_HIGH_INT_S
ET_STATUS
9
CLIF_RFLD_ACT_INT_SET
_STATUS
8
VBUS_MON_LOW_INT_SE
T_STATUS
7
VBUSP_MON_LOW_INT_S
ET_STATUS
6
PVDD_CURLIM_ACT_SET
_STATUS
5
TEMPERROR1_INT_SET_
STATUS
4
TEMPERROR0_INT_SET_
STATUS
3
SUSPEND_
DEFAULTED_INT_SET_ST
ATUS
2
RESERVED
UM10858
User manual
COMPANY PUBLIC
Access
Value
Description
GPIO8 pad going high interrupt set status
-x
0x00
1: Set GPIO8 interrupt. Auto clear after 2 cycles.
GPIO7 pad going high interrupt set status
-x
0x00
1: Set GPIO7 interrupt. Auto clear after 2 cycles.
GPIO6 pad going high interrupt set status
1: Set GPIO6 interrupt. Auto clear after 2 cycles.
-x
0x00
GPIO5 pad going high interrupt set status
-x
0x00
1: Set GPIO5 interrupt. Auto clear after 2 cycles.
GPIO4 pad going high interrupt set status
-x
0x00
1: Set GPIO4 Interrupt. Auto clear after 2 cycles.
GPIO3 pad going high interrupt set status
-x
0x00
1: Set GPIO3 interrupt. Auto clear after 2 cycles.
GPIO2 pad going high interrupt set status
-x
0x00
1: Set GPIO2 interrupt. Auto clear after 2 cycles.
GPIO1 pad going high interrupt set status
-x
0x00
1: Set GPIO1 interrupt. Auto clear after 2 cycles.
-x
0x00
Reserved
VBUSP monitor going high interrupt set status
1: Set VBUSP monitor high interrupt. Auto clear after 2
-x
0x00
cycles.
Clif RF field activity observed interrupt set status
1: Set RF level detected interrupt. Auto clear after 2
-x
0x00
cycles.
VBUS monitor going low interrupt set status
1: Set VBUS monitor low interrupt. Auto clear after 2
-x
0x00
cycles.
VBUSP monitor going low interrupt set status
1: Set VBUSP monitor low interrupt. Auto clear after 2
-x
0x00
cycles.
PVDD current limiter active interrupt set status.
1: Set PVDD current limiter interrupt. Auto clear after 2
-x
0x00
cycles.
Temperature error 1 interrupt set status
1: Set temperature sensor 1 error interrupt. Auto clear
-x
0x00
after 2 cycles.
Temperature error 0 interrupt set status
1: Set temperature sensor 0 error interrupt. Auto clear
-x
0x00
after 2 cycles.
Suspend defaulted interrupt set status
1: Set suspend prevented interrupt. Auto clear after 2
-x
0x00
cycles.
-x
0x00
Reserved
All information provided in this document is subject to legal disclaimers.
Rev. 1.4 — 14 May 2018
314514
UM10858
PN7462 family HW user manual
© NXP B.V. 2018. All rights reserved.
117 of 345