Bit
Symbol
2
T0_MODE_SEL
1
T0_RELOAD_ENAB
LE
0
T0_ENABLE
Table 210. CLIF_TIMER1_CONFIG_REG register (address 007Ch)
* = reset value
Bit
Symbol
31
T1_STOP_ON_T3_E
XPIRED
30
T1_STOP_ON_RX_
STARTED
29
T1_STOP_ON_TX_S
TARTED
28
T1_STOP_ON_RF_
ON_EXT
27
T1_STOP_ON_RF_O
FF_EXT
26
T1_STOP_ON_RF_
ON_INT
25
T1_STOP_ON_RF_
OFF_INT
24
T1_STOP_ON_SIGI
N_ACT
23:19
RESERVED
18
T1_START_ON_T3_
RUNNING
UM10858
User manual
COMPANY PUBLIC
Access
Value
001
010
011
100
101
110
111
R/W
0 – 1
0*
1
R/W
0*, 1
0*
1
R/W
0*, 1
Access
Value
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*,1
R/W
0*,1
R/W
0*,1
R
0
R/W
0*, 1
All information provided in this document is subject to legal disclaimers.
Rev. 1.4 — 14 May 2018
314514
PN7462 family HW user manual
Description
3.39 MHz counter
1.70 MHz counter
848 kHz counter
424 kHz counter
212 kHz counter
106 kHz counter
53 kHz counter
Configuration of the timer T0 clock.
Prescaler is disabled: the timer frequency matches CLIF
clock frequency (13.56 MHz).
Prescaler is enabled: the timer operates on the prescaler
signal frequency (chosen by T0_PRESCALE_SEL).
If set to 0, the timer T0 will stop on expiration.
After expiration, the timer T0 will stop counting, i.e., remain
zero, reset value.
After expiration, the timer T0 will reload its preset value and
continue counting down.
Enables the timer T0
Description
T1_STOP_EVENT: If set the timer T1 is stopped when timer
T3 raises its expiration flag.
T1_STOP_EVENT: If set the timer T1 is stopped when a
data reception begins (1st bit is received).
T1_STOP_EVENT: If set the timer T1 is stopped when a
data transmission begins.
T1_STOP_EVENT: If set the timer T1 is stopped when the
external RF field is detected.
T1_STOP_EVENT: If set the timer T1 is stopped when the
external RF field vanishes.
T1_STOP_EVENT: If set, the timer T1 is stopped when the
internal RF field is turned on.
T1_STOP_EVENT: If set, the timer T1 is stopped when the
internal RF field is turned off.
T1_STOP_EVENT: If set, the timer T1 is stopped when an
activity on SigIn is detected.
Reserved
T1_START_EVENT: If set, the timer T1 is started when the
timer T3 starts running.
UM10858