Table 209. CLIF_TIMER0_CONFIG_REG register (address 0078h)
* = reset value
Bit
Symbol
31
T0_STOP_ON_T3_E
XPIRED
30
T0_STOP_ON_RX_
STARTED
T0_STOP_ON_TX_S
29
TARTED
28
T0_STOP_ON_RF_
ON_EXT
27
T0_STOP_ON_RF_O
FF_EXT
26
T0_STOP_ON_RF_
ON_INT
25
T0_STOP_ON_RF_
OFF_INT
24
T0_STOP_ON_SIGI
N_ACT
23:19
RESERVED
18
T0_START_ON_T3_
RUNNING
17
T0_START_ON_RX_
STARTED
16
T0_START_ON_RX_
ENDED
15
T0_START_ON_TX_
STARTED
14
T0_START_ON_TX_
ENDED
13
T0_START_ON_RF_
ON_EXT
T0_START_ON_RF_
12
OFF_EXT
11
T0_START_ON_RF_
ON_INT
10
T0_START_ON_RF_
OFF_INT
9
T0_START_ON_SIG
IN_ACT
8
T0_START_NOW
7:6
RESERVED
5:3
T0_PRESCALE_SEL
UM10858
User manual
COMPANY PUBLIC
Access
Value
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*,1
R/W
0*,1
R/W
0*,1
R
0
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
R/W
0*, 1
D
0*, 1
R
0
R/W
0h-7h
000
All information provided in this document is subject to legal disclaimers.
Rev. 1.4 — 14 May 2018
314514
PN7462 family HW user manual
Description
T0_STOP_EVENT: If set the timer T0 is stopped when timer
T3 raises its expiration flag.
T0_STOP_EVENT: If set the timer T0 is stopped when a
data reception begins (1st bit is received).
T0_STOP_EVENT: If set the timer T0 is stopped when a
data transmission begins.
T0_STOP_EVENT: If set the timer T0 is stopped when the
external RF field is detected.
T0_STOP_EVENT: If set the timer T0 is stopped when the
external RF field vanishes.
T0_STOP_EVENT: If set, the timer T0 is stopped when the
internal RF field is turned on.
T0_STOP_EVENT: If set, the timer T0 is stopped when the
internal RF field is turned off.
T0_STOP_EVENT: If set, the timer T0 is stopped when an
activity on SigIn is detected.
Reserved
T0_START_EVENT: If set, the timer T0 is started when the
timer T3 starts running.
T0_START_EVENT: If set, the timer T0 is started when a
data reception begins (1st bit is received).
T0_START_EVENT: If set, the timer T0 is started when a
data reception ends.
T0_START_EVENT: If set, the timer T0 is started when a
data transmission begins.
T0_START_EVENT: If set, the timer T0 is started when a
data transmission ends.
T0_START_EVENT: If set, the timer T0 is started when the
external RF field is detected.
T0_START_EVENT: If set, the timer T0 is started when the
external RF field is not detected any more.
T0_START_EVENT: If set, the timer T0 is started when an
internal RF field is turned on.
T0_START_EVENT: If set, the timer T0 is started when an
internal RF field is turned off.
T0_START_EVENT: If set, the timer T0 is started when an
activity on SigIn is detected.
T0_START_EVENT: If set, the timer T0 is started
immediately.
Reserved
Controls frequency/period of the timer T0 when the prescaler
is activated in T0_MODE_SEL.
6.78 MHz counter
UM10858
© NXP B.V. 2018. All rights reserved.
171 of 345