NXP Semiconductors PN7462 series User Manual page 53

Table of Contents

Advertisement

NXP Semiconductors
Bit
Symbol
6
VCC_ILIM_ACT_IRQ_CLEAR_STA
TUS
5
RESERVED
4
PVDD_IRQ_CLEAR_STATUS
3
DCDC_OVERLOAD_IRQ_CLEAR_
STATUS
2
SCVDD_OVERLOAD_IRQ_CLEAR
_STATUS
1
TXLDO_OVERCURRENT_IRQ_CL
EAR_STATUS
0
TEMPSENS_ERROR_IRQ_CLEAR
_STATUS
6.7.1.10 PMU_INTERRUPT_SET_STATUS_REG
This register is a collection of Set Interrupt Status commands with automatic clear if set
by software.
Table 47. PMU_INTERRUPT_SET_STATUS_REG (address offset 0x3FEC)
Bit
Symbol
31:9
RESERVED
8
VBUSMON2_LOW_IRQ_SET_ST
ATUS
7
TXLDO_5V_MON_IRQ_SET_ST
ATUS
6
VCC_ILIM_ACT_IRQ_SET_STAT
US
5
RESERVED
4
PVDD_IRQ_SET_STATUS
3
DCDC_OVERLOAD_IRQ_SET_S
TATUS
2
SCVDD_OVERLOAD_IRQ_SET_
STATUS
1
TXLDO_OVERCURRENT_IRQ_S
ET_STATUS
UM10858
User manual
COMPANY PUBLIC
Access
Value
Description
-X
0x00
Clears status of VCC current limiter active
interrupt. Automatically cleared after 2 cycles if
clear by software
-X
0x00
Reserved
-X
0x00
Clears status of PVDD interrupt. Automatically
cleared after 2 cycles if clear by software
-X
0x00
Clears status of DC-to-DC converter overload
interrupt. Automatically cleared after 2 cycles if
clear by software
-X
0x00
Clears status of SCVD overload interrupt.
Automatically cleared after 2 cycles if clear by
software
-X
0x00
Clears status of TXLDO overcurrent interrupt.
Automatically cleared after 2 cycles if set by
software
-X
0x00
Clears status of temperature sensor interrupt.
Automatically cleared after 2 cycles if set by
software
Access
Value
Description
-X
0x00
Reserved
-X
0x00
Sets status of Vbus monitor 2 going low interrupt
-X
0x00
Sets status of TXLDO 5 V monitor interrupt.
Automatically cleared after 2 cycles if set by
software
-X
0x00
Sets status of VCC current limiter active interrupt.
Automatically cleared after 2 cycles if clear by
software
-X
0x00
Reserved
-X
0x00
Sets status of PVDD interrupt. Automatically
cleared after 2 cycles if clear by software
-X
0x00
Sets status of DC-to-DC converter overload
interrupt. Automatically cleared after 2 cycles if
clear by software
-X
0x00
Sets status of SCVD overload interrupt.
Automatically cleared after 2 cycles if clear by
software
-X
0x00
Sets status of TXLDO overcurrent interrupt.
Automatically cleared after 2 cycles if set by
software
All information provided in this document is subject to legal disclaimers.
Rev. 1.4 — 14 May 2018
314514
UM10858
PN7462 family HW user manual
© NXP B.V. 2018. All rights reserved.