1.6.5.3 Pseudo Input Signal Window

1
Spot Welding Application Using an Air Gun
1.6
Spot Gun Motion Control
5. Specify the signal number.
– Input the numerical value of the desired signal number, and press
[ENTER].
• Be sure to confirm that the allocated general-purpose sig-
nal is not used in the job. If it is used in the job, the signal
is duplicated and the job does not operate normally.
• When the output "WELDING CONDITION PARITY" is set,
the parity number is automatically output during welding
NOTE
condition output. The setting of the parity whether it is odd
or even is established in the parameter.
• In case if the stroke switching signal is the double-solenoid
type (X type 2 step stroke gun mechanical stopper type),
allocate two guns; in case if it is the single-solenoid type
(other guns), allocate one gun.
1. Select {IN/OUT} under the main menu.
2. Select {PSEUDO INPUT SIG}.
– The pseudo input signal window appears.
3. Move the cursor to "ON or "OFF", and press [INTERLOCK] +
SELECT].
– Each time [INTERLOCK] + [SELECT] is pressed, " (OFF)" and "
.
(ON)" alternate
1-39