1.4.2.4 PSEUDO INPUT SIGNAL Window

1
Spot Welding Application Using a Motor Gun
1.4
System Setting (Motor Gun)
The following signals can be validated in the PSEUDO INPUT SIGNAL
window.
• TMR COOL WTR ERR (timer cooling water error)
• GUN COOL WTR ERR (gun cooling water error)
• TRANSTHERMO ERR (transformer thermostat error)
• WELD ON/OFF (welding ON/OFF)
1. Select {IN/OUT} from the main menu.
2. Select {PSEUDO INPUT SIG}.
– The PSEUDO INPUT SIGNAL window appears.
3. Move the cursor to the signal whose validity/invalidity is to be set, and
press [INTERLOCK] + [SELECT].
– Each time [INTERLOCK] + [SELECT] are pressed, " (invalid)" and
" (valid)" alternately appear.
1-40