TOHATSU BFT115A Service Manual page 687

4 stroke
Hide thumbs Also See for BFT115A:
Table of Contents

Advertisement

HOW TO READ A WIRING DIAGRAM
TERMINAL No.
Bl
Black
Br
Brown
Y
Yellow
O
Orange
Bu
Blue
Lb
Light blue
Lg
G
Green
Light green
R
Red
Pink
P
W
White
Gr
Gray
OPTION
COMBINATION
SWITCH
Bl/Y
Bl/Y
W/Bl
W/Bl
INDICATOR
LAMP
(MIL)
Bl/Y
Bl/Y
R/Bu
R/Bu
CONNECTOR/TERMINAL No.
Every connector and terminal has a number to help the users find the location and shape of
the connector and the terminal arrangement by referring to the "Connector general layout
drawing" and/or the "Connector drawing." All the connector/terminal numbers shown in this
Service Manual are either of those shown in this section.
: Connector that joins a harness to a harness (Circled No. in black background)
: Connector that connects to electrical equipment (Circled No. in white background)
: Connector (Circled C followed with No. in white background)
: Terminal (Circled T followed with No. in white background)
: Ground (Circled GND followed with No. in white background)
No. 9
FUSE
(15 A)
ECM
12
PG4
G
WARNL
R/Bu
THL
R/Bl
PB
W/R
K-LINE
Bu
PG3
G
TRMA
Y/Bu
VCC1
Br/Y
VCC2
Br/W
IGP1
Y/Bl
IGP2
Y/Bu
PG1
G/R
VCC3
Lg/Bl
SG1
LOAD
G/R
SG2
G/R
BAT
SCS
Lg
LG1
G/Bl
PG2
G/R
BAT
13
WARNL
3
R/Bu
R/Bu
2
W/Bl
W/Bl
TP SENSOR
MAP SENSOR
6
7
1
2
3
1
2
3
15
20
30
Br/W
R/Bl
G/R
Br/Y
W/R
G/R
G
G/Bl
Bu
G/R
GND2
WIRING DIAGRAMS
SYMBOL OF TERMINAL
It shows the shape of each
terminal to identify whether it is a
male or female terminal.
No. 5
No. 10
FUSE
FUSE
(10 A)
(10 A)
4
11
15
16
W/Bl
Y/R
11
Bu
Bl
DLC
Y/R
Lg
28
G/R
G/R
22
Lg/Bl
Y/Bu
Bl
Bl
GND3
G/Bl G/Bl
W/Bl W/Bl
Bl
Bl
17
20
21
24
6
3
JOINT
CONNECTOR 1
Indicates the ground.
(Circled GND followed with No. in
white background)
JOINT
CONNECTOR 2
TRIM
ANGLE
SENSOR
Bl
29
2
22-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents