3. EOP sensor signal line open or short circuit/
GND line open circuit inspection
Measure the voltage between the EOP sensor 3P
connector
main wire harness side No.2
7
(Yellow/Red)
terminal
terminal.
Is the measurement within 4.75 – 5.25 V?
YES
– Replace the EOP sensor with a new one
and recheck.
NO
– • Repair open or short in the Yellow/Red
wire
• Repair open in the Green/Red wire.
• If the main wire harness is normal,
replace the ECM with a new one, and
recheck.
and
No.3
(Green/Red)
EOP SENSOR 3P CONNECTOR
MAIN WIRE HARNESS SIDE
7
SG2
(Green/Red)
POIL
(Yellow/Red)
FUEL SYSTEM