EXHAUST MANIFOLD REMOVAL/
INSTALLATION
REMOVAL
Remove the following:
– L./R. side cover bracket (page 6-18)
Disconnect the following water tubes:
– Water relief tube A (1)
– Water relief tube B (2)
– Tube (7 × 90 mm) (3)
– Tube (7 × 75 mm) (4)
– Tube (7 × 120 mm) (5)
– Water tube E (6)
Disconnect the A/F sensor 4P connector (1) and
remove it from the connector bracket (2).
Release the four harness band clips (3) from the
connector bracket.
Remove the three bolts (4) and connector bracket.
(1)
(3)
(4)
(6)
(2)
(1)
(3)
FUEL SYSTEM
(5)
(4)
(2)
5-107