VIEWED FROM THE FRONT SIDE:
FRAME GROUND CABLE TERMINALS
Connect the Black, Blue, Green/Red and the Green/White
·
wires to the upper frame ground terminal.
·
Connect the Black/White, Blue, Green/Black and Green
wires to the lower frame ground terminal.
·
Install by pushing the frame ground cable terminals against
the corresponding projections on the crankcase.
HARNESS BAND CLIP
Clamp the ground cable and
main wire harness.
FRAME
GROUND
CABLE
MAIN WIRE
HARNESS
Viewed from the upper side:
PROJECTIONS
FRAME GROUND
TERMINALS
CLIP A
24
HARNESS
STARTER CABLE (+)
BAND CLIP
1P CONNECTOR
SERVICE INFORMATION
GND4
POWER TRIM/TILT RELAY
GROUND CABLE TERMINAL
Install by pushing the ground cable terminal against
the corresponding projection on the crankcase.
POWER TRIM/TILT RELAY
GROUND TERMINAL
PROJECTION
POWER TRIM/TILT
MOTOR WIRE
TRIM ANGLE
SENSOR WIRE